Whole-system duct and dryer vent check with before-and-after photos - you see exactly what came out of your vents
That "$99 whole-house special" is a bait ad - the real number appears once they are in your hallway, or the "clean" is a shop-vac at the register. We photograph the inside of your ducts before and after instead.
Why Irving Homeowners Choose Trane Air Duct Cleaning
CleanRun provides independent Trane air duct cleaning, repair, and sealing service throughout Irving, TX, with written upfront pricing and a documented photo record of every duct run. We are not authorized or endorsed by Trane - we are an independent service provider that diagnoses Trane systems based on field experience across Irving homes and commercial buildings. Our Trane work includes evaporator coil cleaning, air handler cleaning, and duct sealing for XR, XV, XC, and legacy VarTrane systems, with equipment from Rotobrush, Nikro, Abatement Technologies, and Guardsman. Call (682) 297-4068 for a written estimate.
Why Trust CleanRun Air Duct Cleaning Irving for Your Trane Air Duct Cleaning?
Tomas Reyes, our owner, grew up in the Bronx and learned HVAC fundamentals at Bronx Community College before spending years on duct work across metro markets. He moved the operation to Dallas-Fort Worth and has been running Irving Trane service calls throughout the area - including the Las Colinas corridor - for several years now. His habit is pulling inspection photos before any cleaning starts, then leaving a written summary of exactly what the camera showed: settled dust, mold-like growth on duct liner, collapsed flex sections, whatever is actually there. His regulars also notice he keeps a Spanish-language explanation ready for customers who’d rather hear the details in their first language.
We know Trane cabinet geometry cold. The slide-out blower design on XR and XV air handlers, the cabinet-mounted filter rack alignment, the all-aluminum coil layout - these are not abstract diagrams to us. We’ve cleaned and sealed them in Valley Ranch split-levels, in 1980s Las Colinas townhomes with original metal trunk lines, and in commercial rooftop packages along O’Connor Road where the fiberglass duct liner has started shedding particulate into the airstream - experience that also informs our Trane in Euless work. The photo doesn’t lie - let’s look at it together before we talk about next steps.
Every job follows Haven Standard Clause 1: written price delivered before any work starts. No exceptions. Our technicians are background-checked and uniformed under Haven Standard Clause 3: Verified Crews. The 365-Day Done Right Promise is backed in writing on every job.
Common Trane Air Duct Cleaning Problems We Fix in Irving

- All-aluminum evaporator coil pinhole leaks on XR/XV systems. Trane’s all-aluminum coils resist formicary corrosion better than old copper designs, but they can develop pinhole refrigerant leaks that mimic duct or airflow problems. A dirty coil causes short-cycling, and homeowners call us thinking they need duct sealing when the real issue is restricted heat exchange. We clean the coil with foaming agents safe for aluminum fins, then pressure-test to separate a refrigerant problem from a duct problem.
- Blower wheel dust loading from misaligned filter racks. Trane’s cabinet-mounted blower assemblies with the integrated slide-out design can pull unfiltered return air past a gap in the filter rack. The blower wheel and evaporator coil get coated directly, bypassing the filter entirely. In Irving’s prolonged summer heat - 100°F stretches from late May through September - systems run almost continuously, so this bypass deposits months of pollen and dust in weeks. We see this on XR16 and XV18 systems regularly.
- Flex duct sag and tear at attic collars. Trane high-static flex duct runs on longer attic trunks in Irving’s hot, humid summers can sag between supports or tear at the collar connection. The result is pressure imbalance and rooms that never cool properly. Our crew recently cleaned a Trane XR16 system in a 1990s Valley Ranch home where the back bedrooms never cooled and the return filter loaded up within three weeks. Video inspection showed the evaporator coil caked with dust and the return plenum pulling air through a cracked mastic seam. We cleaned the coil and blower, sealed the plenum and takeoffs with mastic, and rebalanced the flex run - supply static dropped and the rooms finally tracked with the thermostat.
- Cracked mastic on older metal trunk lines. Older Trane metal trunk lines in slab or garage installations, common in North and West Irving’s 1950s-1970s ranch stock, have mastic that has dried and cracked over decades. Leakage is measurable at seams and takeoffs, especially where the plenum meets the air handler cabinet. We use aftermarket duct sealant rated above local code, applied after mechanical cleaning of the seam surface.
- Degraded fiberglass duct liner in Las Colinas commercial systems. In the older office towers along O’Connor Road and Northgate Drive, original 1980s fiberglass duct liner on Trane commercial air handlers has degraded and sheds particulate into the airstream. This is a failure mode we encounter routinely in Irving’s commercial workload but almost never in the residential-first call queues of Grand Prairie or Garland. Cleaning requires negative-pressure extraction with HEPA containment, not standard residential methods.
Before
AfterTrane Parts & Our Repair-vs-Replace Approach
We use genuine Trane OEM parts when a cabinet-specific component is required - coil panels, blower housings, filter rack assemblies that must match Trane’s slide-out geometry exactly. For duct sealing, flex runs, and mastic, we use high-quality aftermarket materials that meet or exceed Irving code requirements. Our equipment roster includes Rotobrush and Nikro for residential duct cleaning, Abatement Technologies for commercial negative-pressure jobs, and Guardsman sealants for metal trunk restoration.
If a Trane air handler or coil is failing on multiple fronts, we tell you honestly. Targeted repair makes sense when the cabinet is sound and the issue is isolated - a dirty coil, a cracked plenum seal, a sagging flex run. Replacement is the better long-term call when the coil has multiple pinhole leaks, the blower housing is corroded, or the original metal ductwork has reached the end of its serviceable life. We put both options in writing with prices for each, under Haven Standard Clause 1. Call (682) 297-4068 and we’ll lay out the numbers.
Our Trane Service Process - Step by Step

- 1
Video diagnosis. We feed a camera through every accessible duct run and photograph the evaporator coil, blower wheel, and plenum seams. On Trane systems, we pay specific attention to filter rack alignment and slide-out blower track condition - common leak points that generic inspections miss.
- 2
Written scope and price. Before any panel comes off, you get a written document stating what we found, what we recommend, and what it costs. Haven Standard Clause 1. No verbal estimates.
- 3
Cleaning and repair. We clean the evaporator coil with aluminum-safe foaming agent, remove and clean the blower wheel if loaded with bypass dust, seal metal seams with code-rated mastic, and replace damaged flex runs with properly supported new duct. All work is photographed before and after.
- 4
Static pressure test and rebalance. We measure supply and return static before and after work, verifying that the Trane system is moving design airflow. On variable-speed XV and XC systems, we confirm the ECM blower is operating within its programmed torque range.
- 5
Documented photo record and warranty. You receive the before-and-after photo set as a standard deliverable, plus the written 365-Day Done Right Promise. If it’s not right, we make it right - in writing, not as a favor.
Trane Products We Service & Install in Irving
We service and clean Trane XR and XB series split systems, Trane XV and XC variable-speed and two-stage systems, Trane XR series packaged units common on older Irving homes with limited indoor mechanical space, and Trane VarTrane and 4/5-ton residential air handlers - the same systems we handle for Trane in Grapevine. For duct sealing and flex replacement, we stock Rotobrush cleaning systems, Nikro HEPA vacuums, Honeywell and Aprilaire media filters as upgrades, and Guardsman sealants. We do not stock every Trane OEM coil or blower assembly, but we source cabinet-specific parts within 24-48 hours for jobs where aftermarket alternatives won’t fit the slide-out design.
We Also Service These Brands

CleanRun is not a single-brand shop. We service Lennox and Carrier systems with the same documentation standards and written pricing, and we regularly encounter mixed-brand neighborhoods in Irving where the original builder spec varied by phase. Our technicians carry manuals and common parts for all three brands.
FAQs - Trane Air Duct Cleaning Service in Irving
No. We are an independent service provider - not authorized, sponsored, or endorsed by Trane. We diagnose and clean Trane systems based on field experience across Irving homes and commercial buildings, not manufacturer scripts. Our independence means we can recommend repair vs. replace based on what we find, not a brand-mandated protocol.
Yes, when the part is cabinet-specific and must match Trane’s geometry exactly - coil panels, blower housings, filter rack assemblies. For duct sealing, flex runs, and mastic, we use high-quality aftermarket materials that meet or exceed code. We name the brands: Guardsman sealants, Rotobrush and Nikro cleaning equipment, Abatement Technologies for commercial jobs.
Yes. The aluminum fins on Trane XR and XV coils are thinner and more easily damaged by aggressive bristle brushes or acidic cleaners. We use foaming agents formulated for aluminum, applied at low pressure, then rinsed with controlled water volume. Copper coils can tolerate harsher methods. The wrong approach on a Trane all-aluminum coil will flatten fins and restrict airflow worse than the dirt did.
Usually because unfiltered air is bypassing the filter through a misaligned or damaged filter rack on Trane’s cabinet-mounted blower assembly. Irving’s prolonged summer heat forces near-continuous operation, so the bypass pulls far more dusty air than in milder climates. The filter loads fast because it’s catching what it can, while the blower wheel and coil catch the rest. We inspect the rack alignment on every Trane service and document what we find.
On many XR and XV systems, yes. The slide-out blower design provides access to the coil from the return side without full cabinet disassembly. We remove the blower assembly, block the duct openings, and clean the coil in place with foaming agent and low-pressure rinse. If the coil has pinhole leaks or severe fin damage, we’ll show you the photo and discuss replacement. Call (682) 297-4068 for an exact assessment - estimates are free.
Often yes, if the metal is structurally sound. In North and West Irving’s 1950s-1970s ranch homes, original Trane metal trunk lines frequently have cracked mastic at seams and takeoffs but intact sheet metal. Sealing restores measurable airflow and reduces the load on the air handler. If the metal is rusted through or the original design is undersized for current cooling loads, we’ll tell you that in writing and price replacement. Call (682) 297-4068 and we’ll inspect before quoting.
We measure static pressure at the supply and return plenums, then compare to Trane’s design specs for that model. High return static with normal supply static points to a clogged filter or restricted return duct. Low supply and return static together suggests a blower wheel loaded with dust or a failing ECM motor. Uneven room temperatures with normal overall static usually indicate duct leakage or disconnected flex runs. The numbers tell us where to look - we don’t guess.
Whole-system Trane air duct cleaning in Irving typically runs $380-$620 for a standard residential split system, depending on duct run count, accessibility, and whether the evaporator coil and blower require cleaning. Duct sealing adds $180-$340. Commercial Trane systems in Las Colinas properties are priced per system after inspection. We deliver one flat price per system in writing before work starts - no per-vent pricing, no add-ons once the truck is on your drive. Call (682) 297-4068 for an exact quote - estimates are free.
Book Your Trane Service in Irving, TX

Call (682) 297-4068 to schedule Trane air duct cleaning, repair, or sealing in Irving. A live person answers 24/7. We’ll send a background-checked, uniformed technician with a name badge, inspect your system with a video camera, and deliver a written price before any work begins. Every job includes a documented photo record and the 365-Day Done Right Promise, backed in writing.
Written by Tomas Reyes, Owner at CleanRun Duct Repair & Cleaning, serving Irving since 2013.




Before
After
Before
After